Aurora XS column details

Aurora XS column details

Aurora XS columns are compatible with the SCIEX Optiflow Turbo V source and feature a compact design, ideal for workflows involving column heating with IonOpticks heating solutions.

Is the Aurora XS compatible with your workflows?

We recommend choosing the Aurora XS if:
  1. You're using the SCIEX Optiflow Turbo V ion source, and
  2. You wish to heat your column using the HeatSync™ 2-Channel Controller or IonOpticks Heater Controller (Original).


Aurora XS product range dimensions include:


Aurora Ultimate 25x75 XS
  1. Dimensions: 25cm x 75µm ID, 1.7µm C18
  2. Volume: 1.1μl
  3. Part No. AUR4-25075C18-XS

Aurora Ultimate 25x150 XS
  1. Dimensions: 25cm x 150µm ID, 1.7µm C18
  2. Volume: 4,42μl
  3. Part No. AUR4-250150C18-XS

Aurora Elite 15x75 XS
  1. Dimensions: 15cm x 75µm ID, 1.7µm C18
  2. Volume: 0.66μl
  3. Part No. AUR4-15075C18-XS

Aurora Elite 15x150 XS
  1. Dimensions: 15cm x 150µm ID, 1.7µm C18
  2. Volume: 2.66μl
  3. Part No. AUR4-150150C18-XS


The following applies to all column dimensions:

Column format:
Analytical column
Column type:
Reversed-phase
For use with:
UHPLC
Pore size:
120Å
Max pressure:
>1700 bar
Temp limits:
60°C (low pH)
Particle size:
1.7μm
pH stability:
1-8
Stationary phase:
C18



    • Related Articles

    • Required accessories for Aurora XS column operation

      Depending on your chosen column length, the following accessories may be required to ensure optimal performance: HeatSync™ 2-Channel Controller Introducing the HeatSync range of temperature control solutions, which includes: 1 x HeatSync™ 2-Channel ...
    • Aurora Series column features

      Aurora Series columns are available in four specific compatibility marks, allowing for compatibility with Thermo Scientific, Bruker, and Sciex instruments: Instrument Compatibility Aurora Columns Compatible for use with Thermo Scientific’s Nanospray ...
    • Aurora column details

      The Aurora columns are suited to users operating with the Thermo Scientific Nanospray Flex source, particularly in workflows where column heating is not required or where a third-party heating system is already in use (e.g., Sonation Column Oven). Is ...
    • Aurora XT column product details

      The Aurora XT range is designed for users looking for seamless integration with the Thermo Scientific EASY-Spray and/or Nanospray Flex sources, particularly when column heating is required. Is the Aurora XT compatible with your workflows? We ...
    • Aurora CSI column product details

      The Aurora CSI range columns are compatible with the Bruker CaptiveSpray source, offering a plug-and-play format tailored to Bruker workflows. Is the Aurora CSI compatible with your workflows? We recommend choosing the Aurora CSI if: You're using the ...