Odyssey Series Column Product Information

Odyssey Series Column Product Information

Odyssey Series columns are supplied pre-packed with our high-resolution stationary phase packing material and are ready for use. 

This model is compatible with a column oven (Sonation Column Oven or Bruker Column Toaster recommended) secured to a Bruker CaptiveSpray source or a Thermo Nanospray Flex source.



25cm Odyssey Series column
  1. Dimensions: 25cm x 75µm ID, 1.6µm C18
  2. Volume: 1.1μl
  3. Part No. ODY-25075C18A


15cm Odyssey Series column
  1. Dimensions: 15cm x 75µm ID, 1.6µm C18
  2. Volume: 0.66μl
  3. Part No. ODY-15075C18A

The following applies to both column dimensions:

Column format:
Analytical column
Column type:
Reversed-phase
For use with:
UHPLC
Pore size:
120Å
Max pressure:
1000 bar
Temp limits:
60°C (low pH)
Particle size:
1.6μm
pH stability:
1-8
Stationary phase:
C18
Emitter Tip ID:
6µm

    • Related Articles

    • Aurora Series Column with nanoZero® Product Information

      Aurora Series columns are supplied pre-packed with our high-resolution stationary phase packing material and are ready for use.  This model is compatible with a column oven (Sonation Column Oven recommended) using a Thermo Nanospray Flex source. 25cm ...
    • Aurora Series Column with nanoZero® & CaptiveSpray Insert (CSI) Product Information

      Aurora Series columns are supplied pre-packed with our high-resolution stationary phase packing material and are ready for use.  This model is compatible with a column oven (Sonation Column Oven or Bruker Column Toaster recommended) secured to a ...
    • Odyssey Series Column Features

      Our Odyssey Series columns are differentiated by a key technological advance: a unique packed emitter design that enables maximum mobile phase velocity with no post-column dead volume. This feature maximises chromatographic efficiency and ...
    • Aurora Series Column Features

      Our Aurora Series columns are differentiated by two key technological advances: A unique packed emitter design that enables maximum mobile phase velocity with no post-column dead volume. Our own nanoZero® technology that provides user friendly ‘plug ...
    • Choosing the best column length for your lab

      The best column length for your lab will depend on your sample types, sample cohort size, and preferred performance indicators. Please submit a support ticket if you would like to further discuss your options. Please note that the below lifetime ...