Aurora column product details
The Aurora columns are suited to users operating with the Thermo Scientific Nanospray Flex source, particularly in workflows where column heating is not required or where a third-party heating system is already in use (e.g., Sonation Column Oven).
Is the Aurora compatible with your workflows?
We recommend choosing the Aurora if:
You're using the Thermo Nanospray Flex ion source, and
You either don’t require column heating, or are using an alternative heating system (e.g., Sonation Column Oven) instead of the HeatSync™ 2-Channel Controller or IonOpticks Heater Controller (1st Generation).
Aurora columns are available in the following dimensions:
- Dimensions: 60cm x 75µm ID, 1.7µm C18
- Volume: 2.65μl
- Part Nos. AUR4-60075C18
Aurora Ultimate 25x75
Dimensions: 25cm x 75µm ID, 1.7µm C18
Volume: 1.1μl
Part Nos. AUR4-25075C18
Aurora Ultimate 25x150
Dimensions: 25cm x 150µm ID, 1.7µm C18
Volume: 4.42μl
Part Nos. AUR4-250150C18
Aurora Elite 15x75
- Dimensions: 15cm x 75µm ID, 1.7µm C18
- Volume: 0.66μl
- Part Nos. AUR4-15075C18
Aurora Elite 15x150
- Dimensions: 15cm x 150µm ID, 1.7µm C18
- Volume: 2.66μl
- Part Nos. AUR4-15075C18
Aurora Rapid 5x150
- Dimensions: 5cm x 150µm ID, 1.7µm C18
- Volume: 0.88μl
- Part Nos. AUR4-50150C18
Aurora Rapid 5x75
- Dimensions: 5cm x 75µm ID, 1.7µm C18
- Volume: 0.22μl
- Part Nos. AUR4-5075C18
The following applies to all column dimensions:
Column format:
| Analytical column
|
Column type:
| Reversed-phase
|
For use with:
| UHPLC
|
Pore size:
| 120Å
|
Max pressure:
| >1700 bar
|
Temp limits:
| 60°C (low pH)
|
Particle size:
| 1.7μm
|
pH stability:
| 1-8
|
Stationary phase:
| C18
|
|
|
Related Articles
Odyssey Series column product details
Odyssey Series columns are supplied pre-packed with our high-resolution stationary phase packing material and are ready for use. This model is compatible with a column oven (Sonation Column Oven or Bruker Column Toaster recommended) secured to a ...
Aurora CSI column product details
The Aurora CSI range columns are compatible with the Bruker CaptiveSpray source, offering a plug-and-play format tailored to Bruker workflows. Is the Aurora CSI compatible with your workflows? We recommend choosing the Aurora CSI if: You're using the ...
Aurora XT column product details
The Aurora XT range is designed for users looking for seamless integration with the Thermo Scientific EASY-Spray and/or Nanospray Flex sources, particularly when column heating is required. Is the Aurora XT compatible with your workflows? We ...
Aurora Series column features
Aurora Series columns are available in four specific compatibility marks, allowing for compatibility with Thermo Scientific, Bruker, and Sciex instruments: Instrument Compatibility Aurora Columns Compatible for use with Thermo Scientific’s Nanospray ...
Choosing the ideal Aurora column length for your workflows
Key Considerations for Column Selection Choosing the ideal Aurora Series column length depends on several key factors, including your sample type, cohort size, throughput demands, and specific analytical performance goals. Aurora Series columns are ...